3 resultados para Retina

em Indian Institute of Science - Bangalore - Índia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report the linkage analysis of retinitis pigmentosa (RP) in an Indian family. METHODS: Individuals were examined for symptoms of retinitis pigmentosa and their blood samples were withdrawn for genetic analysis. The disorder was tested for linkage to known 14 adRP and 22 arRP loci using microsatellite markers. RESULTS: Seventeen individuals including seven affecteds participated in the study. All affected individuals had typical RP. The age of onset of the disease ranged from 8-18 years. The disorder in this family segregated either as an autosomal recessive trait with pseudodominance or an autosomal dominant trait. Linkage to an autosomal recessive locus RP28 on chromosome 2p14-p15 was positive with a maximum two-point lod score of 3.96 at theta=0 for D2S380. All affected individuals were homozygous for alleles at D2S2320, D2S2397, D2S380, and D2S136. Recombination events placed the minimum critical region (MCR) for the RP28 gene in a 1.06 cM region between D2S2225 and D2S296. CONCLUSIONS : The present data confirmed linkage of arRP to the RP28 locus in a second Indian family. The RP28 locus was previously mapped to a 16 cM region between D2S1337 and D2S286 in a single Indian family. Haplotype analysis in this family has further narrowed the MCR for the RP28 locus to a 1.06 cM region between D2S2225 and D2S296. Of 15 genes reported in the MCR, 14 genes (KIAA0903, OTX1, MDH1, UGP2, VPS54, PELI1, HSPC159, FLJ20080, TRIP-Br2, SLC1A4, KIAA0582, RAB1A, ACTR2, and SPRED2) are either expressed in the eye or retina. Further study needs to be done to test which of these genes is mutated in patients with RP linked to the RP28 locus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This commentary highlights the effectiveness of optoelectronic properties of polymer semiconductors based on recent results emerging from our laboratory, where these materials are explored as artificial receptors for interfacing with the visual systems. Organic semiconductors based polymer layers in contact with physiological media exhibit interesting photophysical features, which mimic certain natural photoreceptors, including those in the retina. The availability of such optoelectronic materials opens up a gateway to utilize these structures as neuronal interfaces for stimulating retinal ganglion cells. In a recently reported work entitled ``A polymer optoelectronic interface provides visual cues to a blind retina,'' we utilized a specific configuration of a polymer semiconductor device structure to elicit neuronal activity in a blind retina upon photoexcitation. The elicited neuronal signals were found to have several features that followed the optoelectronic response of the polymer film. More importantly, the polymer-induced retinal response resembled the natural response of the retina to photoexcitation. These observations open up a promising material alternative for artificial retina applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stimulus artifacts inhibit reliable acquisition of biological evoked potentials for several milliseconds if an electrode contact is utilized for both electrical stimulation and recording purposes. This hinders the measurement of evoked short-latency biological responses, which is otherwise elicited by stimulation in implantable prosthetic devices. We present an improved stimulus artifact suppression scheme using two electrode simultaneous stimulation and differential readout using high-gain amplifiers. Substantial reduction of artifact duration has been shown possible through the common-mode rejection property of an instrumentation amplifier for electrode interfaces. The performance of this method depends on good matching of electrode-electrolyte interface properties of the chosen electrode pair. A novel calibration algorithm has been developed that helps in artificial matching of impedance and thereby achieves the required performance in artifact suppression. Stimulus artifact duration has been reduced down to 50 mu s from the stimulation-cum-recording electrodes, which is similar to 6x improvement over the present state of the art. The system is characterized with emulated resistor-capacitor loads and a variety of in-vitro metal electrodes dipped in saline environment. The proposed method is going to be useful for closed-loop electrical stimulation and recording studies, such as bidirectional neural prosthesis of retina, cochlea, brain, and spinal cord.